Home > News > Content
Industrial Air Coolers Are Prepared And Run In Advance
Oct 10, 2017


Industrial Air Coolers can be used to extend the life of the FRP Industrial Air Coolers in order to allow the FRP Industrial Air Coolers to be used in the preparation and maintenance of the Industrial Air Coolers. Under normal circumstances, the daily need for FRP Industrial Air Coolers through a comprehensive observation to ensure that its work is normal.
FRP Industrial Air Coolers requires a thorough inspection and cleaning at work. And the work part needs to do a more detailed examination, and so on without any problems before they can proceed. After passing through the inspection door into the tower, it is necessary to clean up the debris and the sludge that the Industrial Air Coolers have at the bottom of the basin, and check whether the pipe is blocked. Use high-pressure water to wash the heat and film on the bottom of the Industrial Air Coolers and drain the effluent through its drain. And also need to test the motor wiring is not correct. Check the FRP Industrial Air Coolers belt belt inside the belt. Check the fan rotation is not more flexible and so on.
In order to make the chiller more efficient, more stable, and to make Industrial Air Coolers safe and safe to use as long as possible, in addition to the Industrial Air Coolers to do the basic inspection work and cleaning work, but also need to do a good job The following maintenance work.
First, Industrial Air Coolers are water-cooled chillers, for the use of belt deceleration device Industrial Air Coolers, every two weeks to check the tension of a belt, inappropriate to adjust; if a few belt tightness is different If the Industrial Air Coolers do not run for a long time, it is best to remove the belt and save it.
Second, if the Industrial Air Coolers are using gear reduction gears, then shut down every month to check the oil level in the gearbox; oil is not enough to add in place; In addition, Industrial Air Coolers every six months to check the oil Color and viscosity, fail to meet the requirements must be replaced; when Industrial Air Coolers cumulative use 5000h, regardless of the oil situation, the gear box must be thoroughly cleaned and replace the oil to ensure that Industrial Air Coolers can provide for the chiller Circulating constant cooling water.
Third, Industrial Air Coolers fan motor is long-term work in the hot and humid environment, in order to ensure its insulation performance, no motor burn accident occurred every year must do a motor insulation test; if not meet the requirements, not only affect the Industrial Air Coolers, more A direct impact on the water-cooled chiller can not work properly, so to promptly deal with or replace the motor.
Fourth, we must pay attention to check whether the filler is damaged, if any, to repair or replace.
5, fan system All bearing grease is generally changed once a year.
6, when the use of chemical agents for water treatment, we should pay attention to the corrosion of the fan blades; in order to slow down the corrosion, the annual removal of a leaf on the corrosive material, even brushing anti-rust paint, or then brush a layer of 0.2mm thick Of the epoxy resin.
Seven, in the winter, part of the water-cooled chiller is not used, the match of Industrial Air Coolers will be shut down during this period may be due to snow and fan blades deformation, then you can take two ways to avoid: one is Stop the blade after the rotation to the vertical angle fixed to the ground; one is to remove the leaves or even with the hub into the room to save.
8, in the winter Industrial Air Coolers stop using, there may be frozen phenomenon, to talk about Industrial Air Coolers water pan and outdoor part of the cooling water system in the water all shine, so as not to freeze equipment and pipes.
For a number of reasons, Industrial Air Coolers' industrial recirculating water is cooled directly without water treatment, and Industrial Air Coolers are cooled directly so that the Industrial Air Coolers fill the slag for a period of time and are prone to scarring, Packing silt, collapse. Resulting in uneven water inside the tower, poor ventilation. The formation of water, water and hydrophobic areas, resulting in wind without water, water without wind situation. Resulting in Industrial Air Coolers cooling effect is greatly reduced. Therefore, in the cooling should be treated on the water quality, to prevent the water quality caused by excessive cooling effect.